Troubleshooting · Breville BES840

the Infuser: No steam / weak steam

Quick answer

No steam usually means the machine isn't at steam temperature, the tank is empty or unseated, the STEAM/HOT WATER dial isn't fully in STEAM, or the wand is blocked. Wait for heat-up, fill and lock the tank, turn the dial fully to STEAM, and clear the wand or descale.

Steam wand produces little or no steam for milk texturing.

Where to look

For weak or no steam, the wand tip and its seal are the usual cause — a blocked tip or worn O-ring.

See the parts for this fix
Steam wand and tipA schematic of the steam wand and its tip, the usual cause of weak or no steam.STEAM ARMWAND TIP ↓

Diagnosis

Work through these checks, in order

1 check · stop as soon as the problem is resolved

  1. 1

    Not at temperature / tank empty / dial not in STEAM / blocked wand

    Medium · Care needed

    No steam results from not reaching steam temperature, an empty or unseated tank, the dial not fully in STEAM, or a blocked wand.

    Check
    1. Let it heat for steam. Allow time to reach steam temperature; the STEAM/HOT WATER light flashes while heating and stops when ready (some condensed water may purge — this is normal).⚠ Steam and the wand are hot; avoid skin contact.
    2. Fill and reseat the tank. Fill the tank and push it down completely to lock into position.
    3. Turn the dial fully to STEAM. Ensure the STEAM/HOT WATER dial is completely rotated to the STEAM position.
    4. Clear the wand / descale. If the steam wand is blocked, follow 'Cleaning the Steam Wand'; if the machine needs decalcifying, run the Descaling procedure.

Fix it

Parts & supplies for this fix

Water Tank Assembly (Infuser)

#SP0010218

Fixes this symptomGenuine OEM
Likely fit

Genuine Breville water tank assembly for the Infuser BES840. Replace if cracked, leaking, or not seating/locking properly (US/CA variant also sold as SP0023715).

Fits
the Infuser (BES840)
Type
genuine
Evidence
source (Authorized retailer) · 2026-11-06

Breville Espresso Machine Cleaning Tablets (BEC250)

#BEC250

Maintenance
Likely fit

Genuine Breville cleaning tablets (8-pack) used in the back-flush cleaning cycle (run when the CLEAN/DESCALE light flashes). Insert the 1 CUP basket with the supplied cleaning disc and one tablet, lock into the group head, and run the ~5-minute cycle (1 CUP + 2 CUP + POWER held ~10s).

Fits
the Infuser (BES840)
Type
cleaner
Evidence
source (Authorized retailer) · 2026-11-06

Breville The Descaler

Maintenance
Likely fit

Genuine Breville descaler. Descale when the CLEAN/DESCALE indicator is solid on: dissolve one sachet in 34 fl.oz (1L) of water and run the descale cycle for the coffee, steam and hot water components, then rinse. Exact retail SKU not yet verified — do not publish an unconfirmed code.

Fits
the Infuser (BES840)
Type
descaler
Evidence
source (Authorized retailer) · 2026-11-06

Breville Water Filter (BWF100)

#BWF100

Maintenance
Likely fit

Genuine Breville replacement water filter. Per the manufacturer's manual, replace the filter every two months (set the date dial 2 months ahead when fitting); replace more often in hard-water areas. Soak a new filter 5 minutes and rinse before use. Keeping the filter fresh reduces how often descaling is needed.

Fits
the Infuser (BES840)
Type
filter
Evidence
source (Authorized retailer) · 2026-11-06

Know the limit

When to call a professional

If the safe checks above don't resolve it, or the fault involves internal wiring, the pump, heating, or pressure system, stop and get professional help.

Contact Breville support →

Sources

Official references

Related guides

Disclosure: some links may be affiliate links. Where an affiliate program is active, we may earn a commission from qualifying purchases at no extra cost to you. This never influences our compatibility assessments.

Information last verified: 2026-11-27